HMS Developments All Articles
Design & Compliance

The Extra Core: How the Second Staircase Is Redrawing the Mid-Rise Floorplate

By HMS Developments Design & Compliance
The Extra Core: How the Second Staircase Is Redrawing the Mid-Rise Floorplate

Photo by Seb Doe on Unsplash

The second staircase is often discussed as a fire safety measure. Commercially, it is a floorplate measure. For a generation of mid-rise residential schemes in Britain — the five, six and seven-storey blocks that have carried so much of the urban housing delivery of the past decade — the requirement to provide a second protected stair fundamentally alters what can be built on a given footprint, and therefore what that footprint is worth.

The transitional period has been the industry's comfort blanket. Schemes already advanced through the system have been able to proceed under the previous arrangements, with the cut-off now falling at the end of September 2026. From that point, the pipeline is uniform: the design flexibilities that many appraisals still quietly assume will no longer be available.

Where the rules bite hardest

The obvious casualties are single-stair schemes above the height threshold — efficient, elegant, and now largely consigned to the lower-rise end of the market. But the more consequential effect is on the ordinary mid-rise block, where a second core does not simply add a stair; it adds a lobby, a protected corridor, additional compartmentation, and a second set of fire doors, firefighting lifts in some configurations, and smoke control provisions.

A second core is not a linear addition. It changes the geometry of the plan. On narrow frontages it can force a deeper building, which reduces daylight penetration and pushes habitable rooms toward single-aspect. On constrained urban sites it can consume the sliver of land that made the scheme viable in the first place. And in conservation areas or tight-grained streets, it can produce elevations that planning committees find difficult to accept.

The net-to-gross arithmetic

For developers, the operative number is net-to-gross efficiency — the proportion of built area that can actually be let or sold. A well-resolved single-core mid-rise scheme has historically achieved efficiency in the low eighties. Introducing a second core, with its associated lobbies and circulation, typically removes between three and six percentage points, and in awkward configurations more.

On a 120-unit scheme, a four-point swing in efficiency is not an abstract design metric. It is a double-digit number of homes, or a materially smaller average unit size, or a set of planning obligations that no longer fit within the appraisal. Multiplied across a portfolio, it is the difference between a land bid that wins and a land bid that loses.

Optioning before the application

The schemes navigating this well are doing the work at the right stage — before the offer, not before the committee. Three approaches are recurring.

The first is the twin-core typology, placing two protected stairs at opposite ends or opposite corners of the plan to preserve a central, daylit band of accommodation. It is efficient where frontage allows, and it produces a building that reads conventionally in the street scene.

The second is the scissor stair, which stacks two intertwined flights within a single footprint. It remains a legitimate solution in defined circumstances, but it demands early fire engineering input and a planning authority comfortable with the approach. It is not a default.

The third is the external or naturally ventilated stair, which can remove a substantial slab of internal circulation from the core and return it to habitable area. Where the elevation can carry it, and where the relevant guidance permits, the savings are meaningful — but it changes the building's external expression, and that is a design conversation, not a technical one.

Each route carries a different planning risk, a different construction cost and a different sales story. The mistake is to defer the choice until the architect has fixed the massing.

Protecting residual land value

The consequence for land acquisition is direct. Any appraisal that assumes pre-2026 core arrangements is overvaluing the site. Sensitivity testing on efficiency, unit count and build cost should be run at the bid stage, with the second core priced in from the outset rather than discovered at technical design.

Where the loss cannot be absorbed, three levers remain. Height can sometimes be traded: an additional storey may recover the lost area, subject to townscape and daylight considerations. Tenure mix can be adjusted, with a greater proportion of smaller units offsetting the efficiency loss. And on some sites, a modest reduction in unit numbers with an uplift in quality and specification will outperform a scheme that has been squeezed to hit a density target.

Compliance as a design brief

There is a temptation to treat the second staircase as a late-stage tax on ambition. The better-run projects are treating it as a brief.

A second core, properly handled, delivers a building with genuinely dual-aspect circulation, better resilience, easier evacuation and a stronger proposition for institutional buyers and their insurers. It can improve the quality of the entrance sequence, provide natural separation between tenures, and create space for the parcel storage and cycle parking that residents now expect.

The requirement is not going away, and the transitional relief is nearly spent. The developers who will look back on this period without regret are those who redrew the floorplate while there was still time to redraw the appraisal.